I. Wind Turbine External Inspection 1. Observe the wind turbine housing for cracks, deformation, severe rust, etc. 2. Check the wind turbine blades for cracks, deformation, and severe wear.

I. Fan External Inspection

1. Observe the fan housing for cracks, deformation, severe rust, etc.

2. Check the fan blades for cracks, deformation, severe wear, etc.

3. Check the fan bearings for oil leakage, severe wear, etc.

4. Check the fan transmission system for looseness and breakage.

5. Check the fan seals for leakage and severe wear.

6. Check the fan lubrication system for oil leakage, overheating, and oil degradation.

7. Check the electrical system for aging wires and damaged insulation.

8. Check the control system for aging and damaged components.

9. Check if the ambient temperature and humidity are suitable for fan operation.

10. Monitor the fan's operating status, including speed, vibration, and sound, to determine whether the fan is operating normally.

II. Fan Bearing Inspection

1. Check the bearings for wear and cracks.

2. Check the lubrication of the bearings, including the quality and quantity of the grease.

3. Check the installation of the bearings, including the tightness of the bearings, axial and radial clearances, etc.

4. Disassemble and clean the bearings; replace damaged bearings and grease.

5. Check the bearing housing for oil leakage; replace damaged oil seals.

6. Check the shaft for axial movement; adjust the axial clearance of the bearings.

7. Check the installation of the bearing housing to ensure that it is securely fastened.

8. Preload the bearings to ensure that the bearings are evenly stressed during operation.

9. Check the grounding of the bearings to ensure good grounding.

10. Lubricate the bearings to ensure good lubrication.
 

Keywords:

Coal mine ventilator

Ventilator

Related News


Tunnel fan structure principle and use

SDF and SD series fans are specifically designed for extra-long and extra-large tunnels in railway, highway, subway, water conservancy and hydropower projects, as well as for local ventilation. In particular, the newly developed "multi-stage variable speed" series tunnel ventilation fans are more suitable for long and large tunnel construction, with significantly better energy-saving effects.

22 Apr,2025

Introduction to environmentally friendly, low-noise FBD axial flow local ventilation fan

The environmentally friendly FBD low-noise axial local ventilation fan is a super low-noise, environmentally friendly ventilation fan developed by our company. This series of fans adopts multiple noise reduction measures. Based on the aerodynamic principles of the fan and the principles of noise generation and propagation, streamlined air intake silencers and inlet/outlet composite silencers have been added.

22 Apr,2025

Introduction to the Non-stop Main Ventilation Fan System for Mines

The main ventilation fan non-stop system for mining is designed to overcome the various shortcomings of the ventilation equipment structure currently used in most mines.

22 Apr,2025

Product Inquiry


*We attach great importance to your opinions and inquiries. If you have any questions about our products and services, please fill out the following form, and we will contact you as soon as possible.